Journal of the American Society of Nephrology
2007 JASN IMPACT FACTOR 7.111 HOME   AUTHOR INFO   EDITORIAL BOARD   SUBSCRIBE   FEEDBACK   ALERTS   HELP 
    advanced
CURRENT ISSUE ARCHIVES JASN Express ONLINE SUBMISSION


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gordon, S. M.
Right arrow Articles by Jarvis, W. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gordon, S. M.
Right arrow Articles by Jarvis, W. R.

Journal of the American Society of Nephrology, Vol 2, 1436-1444, Copyright © 1992 by American Society of Nephrology


REGULAR ARTICLES

Pyrogenic reactions in patients receiving conventional, high- efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin

SM Gordon, CW Oettinger, LA Bland, JC Oliver, MJ Arduino, SM Aguero, SK McAllister, MS Favero and WR Jarvis
Hospital Infections Program, Centers for Disease Control, Atlanta, GA 30333.

High-efficiency (HE) and high-flux (HF) hemodialysis are becoming increasingly popular methods for treating patients with chronic renal failure because they reduce the time required for dialysis treatment. HF and HE dialyzers require bicarbonate dialysate, often prepared from concentrates that can support bacterial growth with endotoxin production. There is a concern that endotoxins or bacteria may cross or interact at the membranes of these dialyzers, triggering the release of endogenous pyrogens (cytokines) by peripheral blood mononuclear cells to cause pyrogenic reactions (PR). To determine the incidence of PR and to examine the association between PR and levels of bacteria and endotoxin in dialysate, a cohort of patients receiving conventional, HE, or HF hemodialysis with bicarbonate dialysate and reprocessed dialyzers at three dialysis centers during a 12-month period was studied prospectively. All dialyzers underwent a test of membrane integrity before use. A total of 19 PR were identified among 18 patients in 26,877 hemodialysis treatments (0.7 PR/1,000 treatments). There was no significant difference in PR rates by treatment modality: conventional, 0.5 per 1,000 (7 PR/13,123 treatments) versus HE, 0.9 per 1,000 (9 PR/11,345) versus HF, 1.2 per 1,000 (3 PR/2,409) (P = 0.21; chi 2 test). Throughout the study period, bacterial counts for dialysate at each center significantly exceeded the Association for the Advancement of Medical Instrumentation's (AAMI) microbiologic standards for dialysate of less than 2,000 CFU/mL (mean, 19,000 CFU/mL), but water used in the reuse of dialyzers tested less than 200 CFU/mL.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
K. van der Linde, B. T. Lim, J. M. M. Rondeel, L. P. M. T. Antonissen, and G. M. Th. de Jong
Improved bacteriological surveillance of haemodialysis fluids: a comparison between Tryptic soy agar and Reasoner's 2A media
Nephrol. Dial. Transplant., October 1, 1999; 14(10): 2433 - 2437.
[Abstract] [Full Text] [PDF]




HOME CURRENT ISSUE ARCHIVES JASN Express ONLINE SUBMISSION AUTHOR INFO
EDITORIAL BOARD SUBSCRIBE FEEDBACK ALERTS HELP