Journal of the American Society of Nephrology
2008 JASN IMPACT FACTOR 7.505 HOME   AUTHOR INFO   EDITORIAL BOARD   SUBSCRIBE   FEEDBACK   ALERTS   HELP 
    advanced
CURRENT ISSUE ARCHIVES JASN Express ONLINE SUBMISSION


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pegues, D. A.
Right arrow Articles by Jarvis, W. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pegues, D. A.
Right arrow Articles by Jarvis, W. R.

Journal of the American Society of Nephrology, Vol 3, 1002-1007, Copyright © 1992 by American Society of Nephrology


REGULAR ARTICLES

A prospective study of pyrogenic reactions in hemodialysis patients using bicarbonate dialysis fluids filtered to remove bacteria and endotoxin

DA Pegues, CW Oettinger, LA Bland, JC Oliver, MJ Arduino, SM Aguero, SK McAllister, SM Gordon, MS Favero and WR Jarvis
Hospital Infections Program, Centers for Disease Control, Atlanta, GA 30333.

Pyrogenic reactions (PR) are a well-recognized complication of hemodialysis and have been associated with dialyzer reuse, high-flux dialysis, and bicarbonate dialysate. However, the roles of bacteria and endotoxin in dialysate for producing PR are not well defined. To determine the effect of removing most bacteria and endotoxin from the dialysate on the incidence of PR, a cohort of chronic hemodialysis patients receiving high-flux, high-efficiency, or conventional hemodialysis at three centers with bicarbonate dialysis fluids that had been filtered with a polysulfone high-flux hemodialyzer was prospectively studied. Unfiltered bicarbonate concentrate had median bacterial and endotoxin concentrations of 479,000 CFU/mL and 39,800 pg/mL, respectively. After filtration of the bicarbonate concentrate at the central proportioner, dialysate had a median 9.2 CFU/mL of bacteria and 17.8 pg/mL of endotoxin. Dialysate filtered at individual proportioning dialysis machines had a median 0.001 CFU/mL of bacteria and 0.19 pg/mL of endotoxin. Nine PR were identified among 303 patients after 28,007 hemodialysis treatments (0.3 PR/1,000 treatments). The rate of PR was similar for the three hemodialysis treatment modalities and for first-use compared with reused dialyzers. Although the PR rate in this study was lower (P = 0.046) than the PR rate of a previous study with unfiltered dialysis fluids (0.7 PR/1,000 treatments), it represents a difference of only 10 PR in over 28,000 treatments. It was concluded that filtration of hemodialysis fluids is efficacious in removing bacterial and endotoxin contamination and can result in a lower incidence of PR in patients receiving high-flux, high-efficiency, or conventional hemodialysis.


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
J. Bommer
Sterile filtration of dialysate: is it really of no use?
Nephrol. Dial. Transplant., October 1, 2001; 16(10): 1992 - 1994.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
R. Perez-Garcia and P. O C. Rodriguez-Benitez
Why and how to monitor bacterial contamination of dialysate?
Nephrol. Dial. Transplant., June 1, 2000; 15(6): 760 - 764.
[Full Text] [PDF]


Home page
JAMAHome page
J. C. Hutter, M. J. Kuehnert, R. R. Wallis, A. D. Lucas, S. Sen, and W. R. Jarvis
Acute Onset of Decreased Vision and Hearing Traced to Hemodialysis Treatment With Aged Dialyzers
JAMA, April 26, 2000; 283(16): 2128 - 2134.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
D. Zimmerman, P. Cotman, R. Ting, S. Karanicolas, and S. W. Tobe
Continuous veno–venous haemodialysis with a novel bicarbonate dialysis solution: prospective cross-over comparison with a lactate buffered solution
Nephrol. Dial. Transplant., October 1, 1999; 14(10): 2387 - 2391.
[Abstract] [Full Text] [PDF]




HOME CURRENT ISSUE ARCHIVES JASN Express ONLINE SUBMISSION AUTHOR INFO
EDITORIAL BOARD SUBSCRIBE FEEDBACK ALERTS HELP