Protein energy malnutrition is common among persons with ESRD and contributes substantially to morbidity and mortality. The usual methods of nutritional assessment, such as anthropometry, can be misleading because of altered tissue hydration. Bioelectrical impedance analysis (BIA) has been recommended by some as a practical nutritional assessment tool but has not been validated in patients with ESRD. Thirty-three stable patients on maintenance hemodialysis were evaluated in an ambulatory clinical research center with simultaneous BIA, dual- energy x-ray absorptiometry, and deuterium oxide (D2O) and sodium bromide (NaBr) isotope dilution studies. Standard determinations of total body water (TBW) and body cell mass (BCM) were obtained and compared with values estimated by BIA. Two separate outpatient BIA measurements were also obtained approximately 2 wk before and after the clinical research center evaluation. BCM estimated by BIA was directly correlated (r = 0.92, P < 0.0001) with BCM determined by DEXA and NaBr. TBW estimated by BIA was directly correlated (r = 0.96, P < 0.0001) with TBW determined by deuterium oxide dilution. The reactance to resistance ratio (Xc/R) derived from BIA was inversely correlated (r = - 0.73, P < 0.0001) with the extracellular water/TBW ratio determined by NaBr/D2O. Bland-Altman analyses showed that for TBW, BIA was in excellent agreement with D2O dilution. BCM was modestly underestimated by BIA compared with the dual-energy x-ray absorptiometry/NaBr standard and was adjusted by linear regression. The coefficients of variation on repeated BIA measurements were below 4%, demonstrating test-retest reliability. BIA is a valid and reliable method of nutritional assessment in maintenance hemodialysis patients.
This article has been cited by other articles:
![]() |
P. Kotanko, N. W. Levin, and F. Zhu Current state of bioimpedance technologies in dialysis Nephrol. Dial. Transplant., March 1, 2008; 23(3): 808 - 812. [Full Text] [PDF] |
||||
![]() |
F. Zhu, M. K. Kuhlmann, G. A. Kaysen, S. Sarkar, C. Kaitwatcharachai, R. Khilnani, L. Stevens, E. F. Leonard, J. Wang, S. Heymsfield, et al. Segment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients J Appl Physiol, February 1, 2006; 100(2): 717 - 724. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. A Kaysen, F. Zhu, S. Sarkar, S. B Heymsfield, J. Wong, C. Kaitwatcharachai, M. K Kuhlmann, and N. W Levin Estimation of total-body and limb muscle mass in hemodialysis patients by using multifrequency bioimpedance spectroscopy Am. J. Clinical Nutrition, November 1, 2005; 82(5): 988 - 995. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Gupta, C. A Lammersfeld, J. L Burrows, S. L Dahlk, P. G Vashi, J. F Grutsch, S. Hoffman, and C. G Lis Bioelectrical impedance phase angle in clinical practice: implications for prognosis in advanced colorectal cancer Am. J. Clinical Nutrition, December 1, 2004; 80(6): 1634 - 1638. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Buchholz, C. Bartok, and D. A. Schoeller The Validity of Bioelectrical Impedance Models in Clinical Populations Nutr Clin Pract, October 1, 2004; 19(5): 433 - 446. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. M. Fagugli, P. Pasini, G. Quintaliani, F. Pasticci, G. Ciao, B. Cicconi, D. Ricciardi, P. V. Santirosi, E. Buoncristiani, F. Timio, et al. Association between extracellular water, left ventricular mass and hypertension in haemodialysis patients Nephrol. Dial. Transplant., November 1, 2003; 18(11): 2332 - 2338. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. D. NICOLA, V. BELLIZZI, R. MINUTOLO, M. CIOFFI, P. GIANNATTASIO, V. TERRACCIANO, C. IODICE, F. UCCELLO, B. MEMOLI, B. R. D. IORIO, et al. Effect of Dialysate Sodium Concentration on Interdialytic Increase of Potassium J. Am. Soc. Nephrol., December 1, 2000; 11(12): 2337 - 2343. [Abstract] [Full Text] |
||||
![]() |
C. P. Earthman, J. R. Matthie, P. M. Reid, I. T. Harper, E. Ravussin, and W. H. Howell A comparison of bioimpedance methods for detection of body cell mass change in HIV infection J Appl Physiol, March 1, 2000; 88(3): 944 - 956. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. C Frankenfield, R. N Cooney, J S. Smith, and W. A Rowe Bioelectrical impedance plethysmographic analysis of body composition in critically injured and healthy subjects Am. J. Clinical Nutrition, March 1, 1999; 69(3): 426 - 431. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Matthie, B. Zarowitz, A. De Lorenzo, A. Andreoli, K. Katzarski, G. Pan, and P. Withers Analytic assessment of the various bioimpedance methods used to estimate body water J Appl Physiol, May 1, 1998; 84(5): 1801 - 1816. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. De Lorenzo, A. Andreoli, J. Matthie, and P. Withers Predicting body cell mass with bioimpedance by using theoretical methods: a technological review J Appl Physiol, May 1, 1997; 82(5): 1542 - 1558. [Abstract] [Full Text] [PDF] |
||||
|
HOME
CURRENT ISSUE
ARCHIVES
JASN Express
ONLINE SUBMISSION
AUTHOR INFO
EDITORIAL BOARD SUBSCRIBE FEEDBACK ALERTS HELP |
Copyright © 2008 by the American Society of Nephrology. Online ISSN: 1533-3450 Print ISSN: 1046-6673