Journal of the American Society of Nephrology
2007 JASN IMPACT FACTOR 7.111 HOME   AUTHOR INFO   EDITORIAL BOARD   SUBSCRIBE   FEEDBACK   ALERTS   HELP 
    advanced
CURRENT ISSUE ARCHIVES JASN Express ONLINE SUBMISSION


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bommer, J.
Right arrow Articles by Urbaschek, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bommer, J.
Right arrow Articles by Urbaschek, R.

Journal of the American Society of Nephrology, Vol 7, 883-888, Copyright © 1996 by American Society of Nephrology


REGULAR ARTICLES

Potential transfer of endotoxin across high-flux polysulfone membranes

J Bommer, KP Becker and R Urbaschek
Nephrology Section, University Heidelberg, Germany.

It has been postulated that synthetic membranes, such as polysulfone membranes, are rather impermeable for endotoxin or endotoxin fragments and can be used for sterile filtration of dialysate. It has never been investigated, however, whether endotoxin permeability may be different in commercially available polysulfone membranes. In vitro, we found a significantly different permeability for endotoxin in two standard dialyzers and one test dialyzer with high-flux polysulfone membranes. In contrast to the F-60 dialyzer with a very low permeability for endotoxin, a stepwise increasing load of endotoxin concentration in the dialysate compartment of the PN 1913 test dialyzer and Primus 1350 polysulfone dialyzer was followed by a stepwise increase of endotoxin in the blood compartment. A significant transfer across the membranes was found when the endotoxin concentration in the dialysate compartment was > 10 ng/mL in the PN 1913 and > 0.5 ng/mL in the Primus 1350. In the latter, about 0.5% of the endotoxin concentration of the dialysate compartment was found in the blood compartment. The data suggest that manufacturers have to evaluate the performance and other properties of their synthetic membranes in detail.


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
J. M. Lamas, M. Alonso, F. Sastre, G. Garcia-Trio, J. Saavedra, and L. Palomares
Ultrapure dialysate and inflammatory response in haemodialysis evaluated by darbepoetin requirements--a randomized study
Nephrol. Dial. Transplant., October 1, 2006; 21(10): 2851 - 2858.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
J. Bommer
Sterile filtration of dialysate: is it really of no use?
Nephrol. Dial. Transplant., October 1, 2001; 16(10): 1992 - 1994.
[Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
P. Brunet and Y. Berland
Water quality and complications of haemodialysis
Nephrol. Dial. Transplant., May 1, 2000; 15(5): 578 - 580.
[Full Text] [PDF]




HOME CURRENT ISSUE ARCHIVES JASN Express ONLINE SUBMISSION AUTHOR INFO
EDITORIAL BOARD SUBSCRIBE FEEDBACK ALERTS HELP