Journal of the American Society of Nephrology
2007 JASN IMPACT FACTOR 7.111 HOME   AUTHOR INFO   EDITORIAL BOARD   SUBSCRIBE   FEEDBACK   ALERTS   HELP 
    advanced
CURRENT ISSUE ARCHIVES JASN Express ONLINE SUBMISSION


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chertow, G. M.
Right arrow Articles by Kay, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chertow, G. M.
Right arrow Articles by Kay, J.

Journal of the American Society of Nephrology, Vol 7, 1235-1240, Copyright © 1996 by American Society of Nephrology


REGULAR ARTICLES

Performance characteristics of a dialysis-related amyloidosis questionnaire

GM Chertow, T Trimbur, EW Karlson, JM Lazarus and J Kay
Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.

To evaluate the effects of beta-2 microglobulin amyloidosis on functional status, a 19-item self-administered questionnaire exploring two major domains-symptoms and disability-was developed as part of this study. Fifteen patients with dialysis-related amyloidosis (DRA) were identified and compared with 15 age-matched control subjects who had been on hemodialysis for less than 24 months. Demographic data, Charlson comorbidity scores, and other clinical and laboratory variables were recorded. Total dialysis-related amyloidosis questionnaire (DRAQ) score (52.1 +/- 16.3 versus 24.4 +/- 6.2, P < 0.0001) and the scores of the symptom (24.5 +/- 7.0 versus 11.5 +/- 2.3, P < 0.0001) and disability (27.5 +/- 10.8 versus 12.9 +/- 4.0, P < 0.0001) subscales were markedly increased among patients with DRA. Baseline characteristics among case and control subjects were similar, except for serum creatinine concentration, which tended to be lower among patients with DRA (8.9 +/- 2.6 versus 11.5 +/- 2.3 mg/dL, P = 0.07). Instrument reliability and internal consistency were high. With a total DRAQ score of 30 or more, the sensitivity and specificity of the instrument were 93% and 80%, respectively. The DRAQ is a reliable, internally consistent, and valid instrument that may be suitable for population screening and clinical practice.





HOME CURRENT ISSUE ARCHIVES JASN Express ONLINE SUBMISSION AUTHOR INFO
EDITORIAL BOARD SUBSCRIBE FEEDBACK ALERTS HELP