| 2007 JASN IMPACT FACTOR 7.111 | HOME AUTHOR INFO EDITORIAL BOARD SUBSCRIBE FEEDBACK ALERTS HELP | |||
| CURRENT ISSUE | ARCHIVES | JASN Express | ONLINE SUBMISSION | |





*
Second Department of Internal Medicine, Osaka City University Medical
School, Osaka, Japan.
Shirasagi Hospital Kidney Center, Osaka, Japan.
Correspondence to Dr. Eiji Ishimura, Second Department of Internal Medicine, Osaka City University Medical School, 1-4-3, Asahi-machi, Abeno-ku, Osaka 545-8585, Japan. Phone: +81-6-6645-3806; Fax: +81-6-6645-3808; E-mail: ish{at}med.osaka-cu.ac.jp
| Abstract |
|---|
|
|
|---|
| Introduction |
|---|
|
|
|---|
Generally, hemodialysis patients have been reported to be undernourished, although initiation of maintenance hemodialysis has been reported to improve not only quality of life but also nutritional status (2,12,14,28,29). However, few reports have clarified the extent to which nutritional status is enhanced by maintenance hemodialysis (14,28,29), and, to our knowledge, none have made use of serial DXA. We used this method to examine whether hemodialysis affects body fat mass. We also analyzed various factors that might influence fat mass in this population. Finally, we considered how well DXA changes reflected the nutritional status of patients who are undergoing hemodialysis.
| Materials and Methods |
|---|
|
|
|---|
Patients underwent three 4-h sessions of hemodialysis per week that used cuprophane dialyzers and bicarbonate-buffered dialysate, which contains 100 mg/dl glucose and 30 mEq/L bicarbonate. All patients were free of significant acute illness at the onset of maintenance hemodialysis as well as through the second DXA measurement approximately 1 yr later. Blood was drawn for routine analysis before a session of hemodialysis. Total protein, serum albumin, calcium, phosphate, and cholesterol were measured by an autoanalyzer.
Measurements of Body Fat Mass
Body fat mass was measured twice by DXA (QDR-1000W; Hologic Inc., Waltham,
MA), with both measurements performed 21 to 24 h after completion of a
dialysis session. The first measurement was carried out between 1 and 2 mo
after initiation of hemodialysis, after stable hemodialysis conditions were
achieved in each patient in terms of stable dry weight and cardiothoracic
ratio (45 ± 5%). The second measurement was performed approximately 1
yr after the first (11 ± 2 mo). Body fat mass was expressed in
kilograms. Changes in body fat mass were calculated as grams per month.
Reproducibility of the fat mass measurement expressed by coefficient of
variation was excellent and has been reported as <1% for body fat mass in
adults
(21,23,25,30).
In our previous study, the reproducibility was <2% in patients who were
undergoing hemodialysis
(31).
Statistical Analyses
Statistical analyses were performed by use of the StatView V system (SAS
Institute, Cary, NC) with a Macintosh computer. All data are expressed as mean
± SD unless otherwise stated. Differences in clinical data between the
times of the first and second DXA measurements were compared by paired
t tests.
2 tests were performed for comparisons
between two groups. Correlation and linear regression analyses were used to
examine the relationship between clinical parameters. Multiple regression
analysis with a forward elimination procedure was used to assess the combined
influence of variables on a dependent variable. The F value was set
at 4.0 at each step. P < 0.05 was considered to indicate
statistical significance.
| Results |
|---|
|
|
|---|
|
Fat Mass and Lean Body Mass
Figure 1 presents changes in
fat mass and lean body mass in each patient. Fat mass at the first measurement
was 10.09 ± 4.12 kg; at the second, it was 11.38 ± 3.84 kg
(Table 1), which was
significantly greater than that at 1 yr previously (P < 0.0001,
paired t test). Lean body mass at the second measurement was 38.91
± 7.04 kg, which was significantly less than that at the first
measurement (39.62 ± 6.50 kg; P < 0.05, paired t
test; Table 1).
|
Comparison between the Patients with Increased and Decreased Fat
Mass
Twenty-two patients showed a decrease in fat mass (1.06 ± 0.96 kg
decrease), and 50 patients showed an increase (2.32 ± 1.76 kg
increase). The baseline serum albumin and cholesterol levels and fat mass of
the patients with an increased fat mass were significantly lower than those
with a decreased fat mass (P < 0.05, unpaired t test;
Table 2). At the second DXA
measurement, however, there were no significant differences between the
patients with increased and decreased fat mass in serum parameters, including
albumin and cholesterol. Fat mass at the second measurement was not
significantly different between patients with increased and decreased fat mass
(11.67 ± 3.32 kg versus 10.68 ± 4.83 kg, respectively;
P = 0.312, unpaired t test)
|
Fat Mass Change per Month
Because the interval between the first and second DXA measurements varied
from 9 to 14 mo (11 ± 2 mo), changes in fat mass between the two
measurements were assessed as grams per month. Fat mass increase was + 118
± 26 g/mo overall (mean ± SEM).
Factors Related to Fat Mass Change
No significant difference in monthly fat mass change was evident between
men and women (133 ± 27 versus 96 ± 50 g/mo, mean
± SEM). Monthly fat mass change in patients with diabetes mellitus was
not significantly different from change in patients without diabetes mellitus
(117 ± 31 versus 118 ± 42 g/mo, mean ± SEM).
By linear-regression analysis, significant negative correlations were noted between monthly fat mass change and baseline serum albumin (r = -0.449, P < 0.0001; Figure 2), as well as baseline fat mass (r = -0.423, P < 0.001; Figure 2) and baseline serum calcium (r = -0.391, P < 0.01). A positive correlation between monthly fat mass change and age showed borderline significance (r = 0.232, P = 0.051). Monthly fat mass change, however, had no significant correlation with body weight, body mass index, blood urea nitrogen, serum creatinine, phosphate, cholesterol, Kt/V, or lean body mass at the time of the first DXA measurement (baseline), although there tended to be a negative correlation between monthly fat mass change and serum cholesterol (r = -0.271, P = 0.102). The monthly fat mass change was not significantly correlated with the changes in serum albumin, cholesterol, or creatinine levels between the two DXA measurements.
|
To analyze factors that affect fat mass changes, we performed multiple regression analysis that used a model in which serum albumin, fat mass, calcium, and age were included as independent variables. These independent variables were selected on the basis of the linear regression analysis. Baseline serum albumin and fat mass showed independent relationships to monthly fat mass change (R2 = 0.323, P < 0.0001; Table 3).
|
| Discussion |
|---|
|
|
|---|
Various methods have been used to assess nutritional status of patients undergoing dialysis. Anthropometric parameters, such as weight, body mass index, skin-fold thickness, and midarm muscle circumference, frequently were used (2,4,10,11,12,13). Body composition changes indicated by bioimpedance measurement (6,10,18,19), computed tomographic determination of fat mass distribution (32), and DXA (11,18,20,21,22,24) also were examined as methods for assessment of nutritional status in dialysis patients. Although anthropometry is easy and inexpensive to perform, it is subject to artifacts from fluid accumulation in patients who are undergoing hemodialysis. Bioimpedance also can be affected by hydration status (6,10,19,24). DXA measures the differential attenuation of two x-rays as they pass through the body, distinguishes bone mineral from soft-tissue mass, and subsequently divides soft-tissue mass into fat mass and fat-free soft-tissue mass (lean body mass). Reproducibility of the measurement is excellent; the reported CV is <1% for body fat mass in adults (21,23,25,30). Unlike estimates from anthropometry and bioimpedance, body fat mass measurements by DXA are affected little by hydration status, even though lean body mass by DXA is affected by hydration (11,21,22,23,24,25,26,27). Reproducibility of the fat mass measurement by DXA expressed by coefficient of variation also was excellent: <2% in patients who were undergoing hemodialysis recently reported by us (31). So far, to our knowledge, nothing has been reported about longitudinal change in body fat mass in patients who are undergoing hemodialysis. In the present study, body fat mass measured by DXA was significantly increased in the first year of maintenance hemodialysis, even though anthropometric parameters such as weight and body mass index did not change significantly. In the present study, lean body mass at the time of second measurement was significantly lower than that at the first measurement (-0.71 ± 2.39 kg; P < 0.05). However, the size and statistical significance of changes in lean body mass were smaller than the increase of body fat mass (P < 0.0001, + 1.29 ± 2.20 kg). The decrease in lean body mass may reflect gradual fluid removal to achieve optimal dry weight during the year of hemodialysis. Lean body mass in patients who are undergoing hemodialysis is affected greatly by hydration status (11,21,22,23).
In our recent study (31), the fat mass of 104 patients who were undergoing hemodialysis with a hemodialysis duration of 7.5 ± 5.1 yr (age, 53.9 ± 9.1; 39 men and 64 women) was 12.55 ± 4.8 kg, which was significantly lower than 167 age- and gender-matched healthy control subjects (14.24 ± 3.70 kg fat mass; 52.9 ± 9.0 yr old; 53 men and 114 women; P < 0.05). The fat mass of the present study at both the first and second measurements was significantly lower than that of both the patients who were undergoing hemodialysis and the healthy control subjects in the previous study (P < 0.05, unpaired t test), although the patient age in the present study was significantly older. In a preliminary study the fat mass of 15 patients with a hemodialysis duration of 15.3 ± 2.7 yr (61 ± 8 yr old; 9 men and 6 women) was 9.23 ± 2.84 kg, which was significantly lower than the fat mass at the second measurement in the present study (P < 0.05, unpaired t test). Taken together, we suggest that the fat mass may increase initially in the first year after hemodialysis initiation and continue to increase slowly thereafter for approximately 7 yr and then decrease thereafter until approximately 15 yr, although further examination that uses a longitudinal follow-up of a large number of patients is required to confirm this.
Several serum parameters have been advocated for assessment of nutritional status in patients who are undergoing hemodialysis in relation to morbidity and mortality. Among these, low serum concentrations of albumin have been reported to be the most significant and useful indicator of poor nutritional status (1,2,3,14,33,34). Low levels of serum creatinine also have been reported to indicate poor nutrition and predict decreased survival in patients who are undergoing hemodialysis (14,33,34,35). After initiation of maintenance hemodialysis, serum albumin and creatinine were reported to increase significantly in the first 6 mo (14,28,29). Poor nutritional status during the first year of dialysis, compared with that thereafter, also has been reported (12). In the present study, serum levels of albumin and creatinine were significantly increased (P < 0.001), which suggests that nutritional status improves in most patients during the first year of dialysis.
We found significantly lower concentrations of baseline serum albumin and cholesterol in patients with increased fat mass than in patients with decreased fat mass. Furthermore, we found a significant negative correlation between monthly fat mass change and baseline serum albumin. Considering that low serum albumin concentrations reflect poor nutritional status (1,2,3,14,33,34), the present study demonstrates that patients with poorer nutritional status accumulated more body fat during the first year of hemodialysis. We also found a significant negative correlation between monthly fat mass change and baseline body fat mass, which indicates more gain at 1 yr when initial fat mass was low. By multiple regression analysis, both of these effects were independent. Therefore, lower body fat mass at baseline represents poorer nutritional status in these patients. Because there was no significant correlation between baseline serum albumin and baseline body fat mass by linear regression analysis (P = 0.1333), we speculate that body fat mass measured by DXA may be a separate aspect of nutritional status clinically different from serum albumin. After initiation of hemodialysis, most patients generally experience increased well-being and improved appetite. Most symptoms associated with uremia, such as loss of appetite, nausea, and generalized fatigue, diminish or disappear. Proteinuria also decreases as residual renal function decreases, which leads to increased serum albumin concentrations (14). One result is improvement of nutritional status (2,12,14), which was related to the increase in body fat mass in the present study.
Malnutrition, reported to be common in maintenance dialysis patients, is associated with increased morbidity and mortality in this population (1,2,3,4,5,6). To assess malnutrition, various laboratory parameters have been advocated, including serum albumin, creatinine, cholesterol, prealbumin, insulin-like growth factor, interleukin-6, C-reactive protein, transferrin, and plasma free amino acids (2,3,6,9,13,14,15,16,17). Body fat mass seems to be a parameter distinct from serum albumin. Serum parameters such as albumin concentrations are affected easily by degree of proteinuria (14,28), particularly in the 6 mo of maintenance hemodialysis, by inflammatory conditions as reflected by C-reactive protein (1,3,6), and also by hydration status (3,14,19,29). Given these limitations of serum parameters, DXA should provide a very useful nutritional marker in these patients.
In conclusion, body fat mass increased significantly during the first year of maintenance hemodialysis. Degree of change per month was influenced by baseline serum albumin and baseline body fat mass in an independent manner. Complementing subjective global assessment, anthropometric methods, and serum parameters, DXA assessment of fat mass change should be a particularly reliable way to evaluate nutritional status in patients who are undergoing hemodialysis.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
M. A. Kamimura, K. M. Majchrzak, L. Cuppari, and L. B. Pupim Protein and Energy Depletion in Chronic Hemodialysis Patients: Clinical Applicability of Diagnostic Tools Nutr Clin Pract, April 1, 2005; 20(2): 162 - 175. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Kamimura and L. Cuppari Reply Nephrol. Dial. Transplant., September 1, 2003; 18(9): 1944 - 1945. [Full Text] [PDF] |
||||
![]() |
K. Iseki, M. Tozawa, and S. Takishita Effect of the duration of dialysis on survival in a cohort of chronic haemodialysis patients Nephrol. Dial. Transplant., April 1, 2003; 18(4): 782 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kato, M. Odamaki, T. Yamamoto, K. Yonemura, Y. Maruyama, H. Kumagai, and A. Hishida Influence of body composition on 5 year mortality in patients on regular haemodialysis Nephrol. Dial. Transplant., February 1, 2003; 18(2): 333 - 340. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
HOME
CURRENT ISSUE
ARCHIVES
JASN Express
ONLINE SUBMISSION
AUTHOR INFO
EDITORIAL BOARD SUBSCRIBE FEEDBACK ALERTS HELP |